Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicD
Frequency50 - 60Hz
Rated voltage240V
Current limiting class-
Voltage typeOther
Over voltage category4
Built-in depth69mm
Rated current4A
Pollution degree3
Width in number of modular spacings1.0
Rated insulation voltage Ui500V
Number of protected poles1
Degree of protection (IP)IP20
Explosion-proofNo
Power loss1.4W
Connectable conductor cross section multi-wired0.75 - 25mm²
Flush-mounted installationNo
Ambient temperature during operating-40 - 70°C
Additional equipment possibleYes
Connectable conductor cross section solid-core0.75 - 35mm²
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Number of poles (total)1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated impulse withstand voltage Uimp6kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS381001R0041 | S301P-D4

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

D

Frequency

50 .. 60Hz

Rated voltage

240V

Current limiting class

-

Voltage type

Other

Over voltage category

4

Built-in depth

69mm

Rated current

4A

Pollution degree

3

Width in number of modular spacings

1.0

Rated insulation voltage Ui

500V

Number of protected poles

1

Degree of protection (IP)

IP20

Explosion-proof

Power loss

1.4W

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Flush-mounted installation

Ambient temperature during operating

-40 .. 70°C

Additional equipment possible

Connectable conductor cross section solid-core

0.75 .. 35mm²

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Number of poles (total)

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated impulse withstand voltage Uimp

6kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.