Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)1
Rated current6A
Number of protected poles1
Built-in depth69mm
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated insulation voltage Ui500V
Power loss0.8W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Frequency50 - 60Hz
Release characteristicD
Current limiting class-
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated voltage240V
Additional equipment possibleYes
Connectable conductor cross section multi-wired0.75 - 25mm²
Flush-mounted installationNo
Over voltage category4
Ambient temperature during operating-40 - 70°C
Degree of protection (IP)IP20
Width in number of modular spacings1.0
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core0.75 - 35mm²
Pollution degree3
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS381001R0061 | S301P-D6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

1

Rated current

6A

Number of protected poles

1

Built-in depth

69mm

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated insulation voltage Ui

500V

Power loss

0.8W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Frequency

50 .. 60Hz

Release characteristic

D

Current limiting class

-

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated voltage

240V

Additional equipment possible

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Flush-mounted installation

Over voltage category

4

Ambient temperature during operating

-40 .. 70°C

Degree of protection (IP)

IP20

Width in number of modular spacings

1.0

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0.75 .. 35mm²

Pollution degree

3

Explosion-proof

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.