Aleta.hr
Main Product Image

2CDS381001R0251 | S301P-D25

Code: 1997077

ManufacturerABB
Catalog number2CDS381001R0251
EAN code4016779080361

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)1
Number of protected poles1
Release characteristicD
Built-in depth69mm
Rated voltage240V
Rated impulse withstand voltage Uimp6kV
Rated current25A
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Power loss2.3W
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated insulation voltage Ui500V
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Current limiting class-
Over voltage category4
Pollution degree3
Additional equipment possibleYes
Degree of protection (IP)IP20
Width in number of modular spacings1.0
Ambient temperature during operating-40 - 70°C
Concurrently switching neutral conductorNo
Explosion-proofNo
Flush-mounted installationNo
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS381001R0251 | S301P-D25

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

1

Number of protected poles

1

Release characteristic

D

Built-in depth

69mm

Rated voltage

240V

Rated impulse withstand voltage Uimp

6kV

Rated current

25A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Power loss

2.3W

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated insulation voltage Ui

500V

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Current limiting class

-

Over voltage category

4

Pollution degree

3

Additional equipment possible

Degree of protection (IP)

IP20

Width in number of modular spacings

1.0

Ambient temperature during operating

-40 .. 70°C

Concurrently switching neutral conductor

Explosion-proof

Flush-mounted installation

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.