Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Built-in depth69mm
Rated current32A
Number of protected poles1
Width in number of modular spacings1.0
Rated insulation voltage Ui500V
Power loss2.9W
Connectable conductor cross section solid-core0.75 - 35mm²
Rated voltage240V
Pollution degree3
Over voltage category4
Frequency50 - 60Hz
Degree of protection (IP)IP20
Additional equipment possibleYes
Connectable conductor cross section multi-wired0.75 - 25mm²
Concurrently switching neutral conductorNo
Ambient temperature during operating-40 - 70°C
Explosion-proofNo
Flush-mounted installationNo
Current limiting class-
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Release characteristicB
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS381001R0325 | S301P-B32

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Built-in depth

69mm

Rated current

32A

Number of protected poles

1

Width in number of modular spacings

1.0

Rated insulation voltage Ui

500V

Power loss

2.9W

Connectable conductor cross section solid-core

0.75 .. 35mm²

Rated voltage

240V

Pollution degree

3

Over voltage category

4

Frequency

50 .. 60Hz

Degree of protection (IP)

IP20

Additional equipment possible

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Concurrently switching neutral conductor

Ambient temperature during operating

-40 .. 70°C

Explosion-proof

Flush-mounted installation

Current limiting class

-

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Release characteristic

B

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.