Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Built-in depth69mm
Rated current10A
Connectable conductor cross section solid-core0.75 - 35mm²
Concurrently switching neutral conductorNo
Number of protected poles1
Rated insulation voltage Ui500V
Connectable conductor cross section multi-wired0.75 - 25mm²
Over voltage category4
Additional equipment possibleYes
Degree of protection (IP)IP20
Ambient temperature during operating-40 - 70°C
Rated voltage240V
Pollution degree3
Power loss2W
Frequency50 - 60Hz
Explosion-proofNo
Release characteristicZ
Flush-mounted installationNo
Width in number of modular spacings1.0
Current limiting class-
Number of poles (total)1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated impulse withstand voltage Uimp6kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS381001R0428 | S301P-Z10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Built-in depth

69mm

Rated current

10A

Connectable conductor cross section solid-core

0.75 .. 35mm²

Concurrently switching neutral conductor

Number of protected poles

1

Rated insulation voltage Ui

500V

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Over voltage category

4

Additional equipment possible

Degree of protection (IP)

IP20

Ambient temperature during operating

-40 .. 70°C

Rated voltage

240V

Pollution degree

3

Power loss

2W

Frequency

50 .. 60Hz

Explosion-proof

Release characteristic

Z

Flush-mounted installation

Width in number of modular spacings

1.0

Current limiting class

-

Number of poles (total)

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated impulse withstand voltage Uimp

6kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.