Technical specifications

Voltage typeOther
Rated voltage240V
Built-in depth69mm
Rated current13A
Power loss1.8W
Over voltage category4
Width in number of modular spacings1.0
Pollution degree3
Number of protected poles1
Rated insulation voltage Ui500V
Degree of protection (IP)IP20
Current limiting class-
Explosion-proofNo
Release characteristicK
Concurrently switching neutral conductorNo
Frequency50 - 60Hz
Additional equipment possibleYes
Connectable conductor cross section multi-wired0.75 - 25mm²
Number of poles (total)1
Connectable conductor cross section solid-core0.75 - 35mm²
Flush-mounted installationNo
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Ambient temperature during operating-40 - 70°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS381001R0447 | S301P-K13

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Rated voltage

240V

Built-in depth

69mm

Rated current

13A

Power loss

1.8W

Over voltage category

4

Width in number of modular spacings

1.0

Pollution degree

3

Number of protected poles

1

Rated insulation voltage Ui

500V

Degree of protection (IP)

IP20

Current limiting class

-

Explosion-proof

Release characteristic

K

Concurrently switching neutral conductor

Frequency

50 .. 60Hz

Additional equipment possible

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Number of poles (total)

1

Connectable conductor cross section solid-core

0.75 .. 35mm²

Flush-mounted installation

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Ambient temperature during operating

-40 .. 70°C