Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Number of poles (total)1
Release characteristicK
Number of protected poles1
Rated current13A
Rated voltage240V
Rated impulse withstand voltage Uimp6kV
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Voltage typeOther
Current limiting class-
Power loss1.8W
Connectable conductor cross section multi-wired0.75 - 25mm²
Degree of protection (IP)IP20
Pollution degree3
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Width in number of modular spacings1.0
Ambient temperature during operating-40 - 70°C
Explosion-proofNo
Additional equipment possibleYes
Connectable conductor cross section solid-core0.75 - 35mm²
Over voltage category4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS381001R0447 | S301P-K13

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Number of poles (total)

1

Release characteristic

K

Number of protected poles

1

Rated current

13A

Rated voltage

240V

Rated impulse withstand voltage Uimp

6kV

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Voltage type

Other

Current limiting class

-

Power loss

1.8W

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Degree of protection (IP)

IP20

Pollution degree

3

Flush-mounted installation

Concurrently switching neutral conductor

Width in number of modular spacings

1.0

Ambient temperature during operating

-40 .. 70°C

Explosion-proof

Additional equipment possible

Connectable conductor cross section solid-core

0.75 .. 35mm²

Over voltage category

4

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.