Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Pollution degree3
Current limiting class-
Frequency50 - 60Hz
Built-in depth69mm
Degree of protection (IP)IP20
Rated voltage240V
Width in number of modular spacings1.0
Over voltage category4
Concurrently switching neutral conductorNo
Power loss3.9W
Rated insulation voltage Ui500V
Number of protected poles1
Explosion-proofNo
Rated current50A
Release characteristicK
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Number of poles (total)1
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Connectable conductor cross section multi-wired0.75 - 25mm²
Flush-mounted installationNo
Ambient temperature during operating-40 - 70°C
Connectable conductor cross section solid-core0.75 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS381001R0577 | S301P-K50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Pollution degree

3

Current limiting class

-

Frequency

50 .. 60Hz

Built-in depth

69mm

Degree of protection (IP)

IP20

Rated voltage

240V

Width in number of modular spacings

1.0

Over voltage category

4

Concurrently switching neutral conductor

Power loss

3.9W

Rated insulation voltage Ui

500V

Number of protected poles

1

Explosion-proof

Rated current

50A

Release characteristic

K

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Number of poles (total)

1

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Flush-mounted installation

Ambient temperature during operating

-40 .. 70°C

Connectable conductor cross section solid-core

0.75 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA