Aleta.hr
Main Product Image

2CDS381001R0608 | S301P-Z63

Code: 1997115

ManufacturerABB
Catalog number2CDS381001R0608
EAN code4016779079969

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage240V
Built-in depth69mm
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Release characteristicZ
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Voltage typeOther
Rated current63A
Number of protected poles1
Power loss6W
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Current limiting class-
Rated insulation voltage Ui500V
Over voltage category4
Concurrently switching neutral conductorNo
Pollution degree3
Flush-mounted installationNo
Connectable conductor cross section solid-core0.75 - 35mm²
Width in number of modular spacings1.0
Ambient temperature during operating-40 - 70°C
Connectable conductor cross section multi-wired0.75 - 25mm²
Degree of protection (IP)IP20
Additional equipment possibleYes
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS381001R0608 | S301P-Z63

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

240V

Built-in depth

69mm

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Release characteristic

Z

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Voltage type

Other

Rated current

63A

Number of protected poles

1

Power loss

6W

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Current limiting class

-

Rated insulation voltage Ui

500V

Over voltage category

4

Concurrently switching neutral conductor

Pollution degree

3

Flush-mounted installation

Connectable conductor cross section solid-core

0.75 .. 35mm²

Width in number of modular spacings

1.0

Ambient temperature during operating

-40 .. 70°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Degree of protection (IP)

IP20

Additional equipment possible

Explosion-proof

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.