Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Concurrently switching neutral conductorNo
Voltage typeOther
Current limiting class-
Explosion-proofNo
Frequency50 - 60Hz
Pollution degree3
Release characteristicC
Degree of protection (IP)IP20
Number of protected poles1
Power loss1.3W
Built-in depth69mm
Rated voltage240V
Rated current0.5A
Width in number of modular spacings1.0
Rated insulation voltage Ui500V
Over voltage category4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Number of poles (total)1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Additional equipment possibleYes
Ambient temperature during operating-40 - 70°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Connectable conductor cross section multi-wired0.75 - 25mm²
Rated impulse withstand voltage Uimp6kV
Flush-mounted installationNo
Connectable conductor cross section solid-core0.75 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS381001R0984 | S301P-C0.5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Concurrently switching neutral conductor

Voltage type

Other

Current limiting class

-

Explosion-proof

Frequency

50 .. 60Hz

Pollution degree

3

Release characteristic

C

Degree of protection (IP)

IP20

Number of protected poles

1

Power loss

1.3W

Built-in depth

69mm

Rated voltage

240V

Rated current

0.5A

Width in number of modular spacings

1.0

Rated insulation voltage Ui

500V

Over voltage category

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Number of poles (total)

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Additional equipment possible

Ambient temperature during operating

-40 .. 70°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Rated impulse withstand voltage Uimp

6kV

Flush-mounted installation

Connectable conductor cross section solid-core

0.75 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.