Aleta.hr
Main Product Image

2CDS381103R0218 | S301P-Z1NA

Code: 1997152

ManufacturerABB
Catalog number2CDS381103R0218
EAN code4016779079587

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current1A
Built-in depth69mm
Number of poles (total)2
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Current limiting class-
Rated voltage240V
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Release characteristicZ
Power loss4.4W
Voltage typeOther
Number of protected poles1
Frequency50 - 60Hz
Flush-mounted installationNo
Width in number of modular spacings2.0
Pollution degree3
Over voltage category4
Additional equipment possibleYes
Connectable conductor cross section solid-core0.75 - 35mm²
Explosion-proofNo
Concurrently switching neutral conductorYes
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-40 - 70°C
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS381103R0218 | S301P-Z1NA

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

1A

Built-in depth

69mm

Number of poles (total)

2

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Current limiting class

-

Rated voltage

240V

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Release characteristic

Z

Power loss

4.4W

Voltage type

Other

Number of protected poles

1

Frequency

50 .. 60Hz

Flush-mounted installation

Width in number of modular spacings

2.0

Pollution degree

3

Over voltage category

4

Additional equipment possible

Connectable conductor cross section solid-core

0.75 .. 35mm²

Explosion-proof

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-40 .. 70°C

Degree of protection (IP)

IP20