Aleta.hr
Main Product Image

2CDS381103R0257 | S301P-K1.6NA

Code: 1997156

ManufacturerABB
Catalog number2CDS381103R0257
EAN code4016779079549

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Release characteristicK
Number of protected poles1
Rated current1.6A
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated insulation voltage Ui500V
Voltage typeOther
Number of poles (total)2
Power loss2.6W
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Current limiting class-
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated voltage240V
Flush-mounted installationNo
Concurrently switching neutral conductorYes
Ambient temperature during operating-40 - 70°C
Additional equipment possibleYes
Degree of protection (IP)IP20
Over voltage category4
Explosion-proofNo
Pollution degree3
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Width in number of modular spacings2.0
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS381103R0257 | S301P-K1.6NA

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Release characteristic

K

Number of protected poles

1

Rated current

1.6A

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated insulation voltage Ui

500V

Voltage type

Other

Number of poles (total)

2

Power loss

2.6W

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Current limiting class

-

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated voltage

240V

Flush-mounted installation

Concurrently switching neutral conductor

Ambient temperature during operating

-40 .. 70°C

Additional equipment possible

Degree of protection (IP)

IP20

Over voltage category

4

Explosion-proof

Pollution degree

3

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Width in number of modular spacings

2.0