Aleta.hr
Main Product Image

2CDS381103R0325 | S301P-B32NA

Code: 1997164

ManufacturerABB
Catalog number2CDS381103R0325
EAN code4016779079464

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicB
Built-in depth69mm
Number of poles (total)2
Rated current32A
Rated impulse withstand voltage Uimp6kV
Number of protected poles1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V20kA
Voltage typeOther
Power loss5.8W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Current limiting class-
Rated voltage240V
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Flush-mounted installationNo
Concurrently switching neutral conductorYes
Pollution degree3
Over voltage category4
Connectable conductor cross section multi-wired0.75 - 25mm²
Additional equipment possibleYes
Connectable conductor cross section solid-core0.75 - 35mm²
Explosion-proofNo
Degree of protection (IP)IP20
Width in number of modular spacings2.0
Ambient temperature during operating-40 - 70°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS381103R0325 | S301P-B32NA

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

B

Built-in depth

69mm

Number of poles (total)

2

Rated current

32A

Rated impulse withstand voltage Uimp

6kV

Number of protected poles

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

20kA

Voltage type

Other

Power loss

5.8W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Current limiting class

-

Rated voltage

240V

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Flush-mounted installation

Concurrently switching neutral conductor

Pollution degree

3

Over voltage category

4

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Additional equipment possible

Connectable conductor cross section solid-core

0.75 .. 35mm²

Explosion-proof

Degree of protection (IP)

IP20

Width in number of modular spacings

2.0

Ambient temperature during operating

-40 .. 70°C

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.