Aleta.hr
Main Product Image

2CDS381103R0338 | S301P-Z4NA

Code: 1997166

ManufacturerABB
Catalog number2CDS381103R0338
EAN code4016779079440

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicZ
Rated voltage240V
Built-in depth69mm
Frequency50 - 60Hz
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Number of protected poles1
Power loss4.4W
Current limiting class-
Number of poles (total)2
Rated current4A
Rated impulse withstand voltage Uimp6kV
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V100kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Concurrently switching neutral conductorYes
Additional equipment possibleYes
Degree of protection (IP)IP20
Over voltage category4
Flush-mounted installationNo
Width in number of modular spacings2.0
Pollution degree3
Connectable conductor cross section solid-core0.75 - 35mm²
Ambient temperature during operating-40 - 70°C
Connectable conductor cross section multi-wired0.75 - 25mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS381103R0338 | S301P-Z4NA

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

Z

Rated voltage

240V

Built-in depth

69mm

Frequency

50 .. 60Hz

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Number of protected poles

1

Power loss

4.4W

Current limiting class

-

Number of poles (total)

2

Rated current

4A

Rated impulse withstand voltage Uimp

6kV

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Concurrently switching neutral conductor

Additional equipment possible

Degree of protection (IP)

IP20

Over voltage category

4

Flush-mounted installation

Width in number of modular spacings

2.0

Pollution degree

3

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-40 .. 70°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Explosion-proof

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.