Aleta.hr
Main Product Image

2CDS381103R0378 | S301P-Z6NA

Code: 1997168

ManufacturerRAZNO
Catalog number2CDS381103R0378
Type
EAN code4016779079426

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Rated impulse withstand voltage Uimp

6kV

Number of poles (total)

2

Rated current

6A

Rated voltage

240V

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Release characteristic

Z

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Current limiting class

-

Number of protected poles

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Power loss

5W

Frequency

50 - 60Hz

Width in number of modular spacings

2.0

Flush-mounted installation

No

Pollution degree

3

Over voltage category

4

Additional equipment possible

Yes

Concurrently switching neutral conductor

Yes

Degree of protection (IP)

IP20

Explosion-proof

No

Connectable conductor cross section solid-core

0.75 - 35mm²

Ambient temperature during operating

-40 - 70°C

Connectable conductor cross section multi-wired

0.75 - 25mm²


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CDS381103R0378 | S301P-Z6NA

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Rated impulse withstand voltage Uimp

6kV

Number of poles (total)

2

Rated current

6A

Rated voltage

240V

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Release characteristic

Z

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

100kA

Current limiting class

-

Number of protected poles

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Power loss

5W

Frequency

50 .. 60Hz

Width in number of modular spacings

2.0

Flush-mounted installation

Pollution degree

3

Over voltage category

4

Additional equipment possible

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-40 .. 70°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²