  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Pollution degree3
Frequency50 - 60Hz
Release characteristicB
Voltage typeOther
Width in number of modular spacings2.0
Rated current40A
Connectable conductor cross section solid-core0.75 - 35mm²
Explosion-proofNo
Degree of protection (IP)IP20
Rated voltage240V
Over voltage category4
Number of protected poles1
Concurrently switching neutral conductorYes
Power loss5.8W
Current limiting class-
Connectable conductor cross section multi-wired0.75 - 25mm²
Rated insulation voltage Ui500V
Flush-mounted installationNo
Number of poles (total)2
Ambient temperature during operating-40 - 70°C
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V20kA
Rated impulse withstand voltage Uimp6kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS381103R0405 | S301P-B40NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Pollution degree

3

Frequency

50 .. 60Hz

Release characteristic

B

Voltage type

Other

Width in number of modular spacings

2.0

Rated current

40A

Connectable conductor cross section solid-core

0.75 .. 35mm²

Explosion-proof

Degree of protection (IP)

IP20

Rated voltage

240V

Over voltage category

4

Number of protected poles

1

Concurrently switching neutral conductor

Power loss

5.8W

Current limiting class

-

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Rated insulation voltage Ui

500V

Flush-mounted installation

Number of poles (total)

2

Ambient temperature during operating

-40 .. 70°C

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

20kA

Rated impulse withstand voltage Uimp

6kV