Catalog number2CDS381103R0505
EAN code4016779079273

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)2
Release characteristicB
Rated voltage240V
Rated current50A
Rated insulation voltage Ui500V
Built-in depth69mm
Number of protected poles1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V15kA
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Power loss7.4W
Frequency50 - 60Hz
Current limiting class-
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Pollution degree3
Concurrently switching neutral conductorYes
Over voltage category4
Width in number of modular spacings2.0
Flush-mounted installationNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Additional equipment possibleYes
Explosion-proofNo
Ambient temperature during operating-40 - 70°C
Connectable conductor cross section solid-core0.75 - 35mm²
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS381103R0505 | S301P-B50NA

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Release characteristic

B

Rated voltage

240V

Rated current

50A

Rated insulation voltage Ui

500V

Built-in depth

69mm

Number of protected poles

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

15kA

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Power loss

7.4W

Frequency

50 .. 60Hz

Current limiting class

-

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Pollution degree

3

Concurrently switching neutral conductor

Over voltage category

4

Width in number of modular spacings

2.0

Flush-mounted installation

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Additional equipment possible

Explosion-proof

Ambient temperature during operating

-40 .. 70°C

Connectable conductor cross section solid-core

0.75 .. 35mm²

Degree of protection (IP)

IP20