Aleta.hr
Main Product Image

2CDS381103R0517 | S301P-K25NA

Code: 1997182

ManufacturerABB
Catalog number2CDS381103R0517
EAN code4016779079266

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles1
Rated voltage240V
Rated current25A
Number of poles (total)2
Rated impulse withstand voltage Uimp6kV
Built-in depth69mm
Release characteristicK
Voltage typeOther
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Current limiting class-
Power loss6.4W
Frequency50 - 60Hz
Pollution degree3
Concurrently switching neutral conductorYes
Flush-mounted installationNo
Additional equipment possibleYes
Width in number of modular spacings2.0
Explosion-proofNo
Ambient temperature during operating-40 - 70°C
Degree of protection (IP)IP20
Over voltage category4
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS381103R0517 | S301P-K25NA

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

1

Rated voltage

240V

Rated current

25A

Number of poles (total)

2

Rated impulse withstand voltage Uimp

6kV

Built-in depth

69mm

Release characteristic

K

Voltage type

Other

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Current limiting class

-

Power loss

6.4W

Frequency

50 .. 60Hz

Pollution degree

3

Concurrently switching neutral conductor

Flush-mounted installation

Additional equipment possible

Width in number of modular spacings

2.0

Explosion-proof

Ambient temperature during operating

-40 .. 70°C

Degree of protection (IP)

IP20

Over voltage category

4

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.