Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Voltage typeOther
Rated current6A
Rated voltage415V
Rated insulation voltage Ui500V
Frequency50 - 60Hz
Explosion-proofNo
Current limiting class-
Release characteristicD
Over voltage category4
Width in number of modular spacings2.0
Pollution degree3
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Flush-mounted installationNo
Ambient temperature during operating-40 - 70°C
Connectable conductor cross section solid-core0.75 - 35mm²
Number of protected poles2
Connectable conductor cross section multi-wired0.75 - 25mm²
Power loss1.6W
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V100kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS382001R0061 | S302P-D6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Voltage type

Other

Rated current

6A

Rated voltage

415V

Rated insulation voltage Ui

500V

Frequency

50 .. 60Hz

Explosion-proof

Current limiting class

-

Release characteristic

D

Over voltage category

4

Width in number of modular spacings

2.0

Pollution degree

3

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Additional equipment possible

Flush-mounted installation

Ambient temperature during operating

-40 .. 70°C

Connectable conductor cross section solid-core

0.75 .. 35mm²

Number of protected poles

2

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Power loss

1.6W

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

100kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.