Aleta.hr
Main Product Image

2CDS382001R0087 | S302P-K0.2

Code: 1997210

ManufacturerABB
Catalog number2CDS382001R0087
EAN code4016779078962

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Number of protected poles2
Release characteristicK
Number of poles (total)2
Rated voltage415V
Voltage typeOther
Rated current0.2A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp6kV
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Power loss2.2W
Current limiting class-
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V100kA
Flush-mounted installationNo
Additional equipment possibleYes
Pollution degree3
Width in number of modular spacings2.0
Connectable conductor cross section multi-wired0.75 - 25mm²
Over voltage category4
Degree of protection (IP)IP20
Connectable conductor cross section solid-core0.75 - 35mm²
Ambient temperature during operating-40 - 70°C
Explosion-proofNo
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS382001R0087 | S302P-K0.2

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Number of protected poles

2

Release characteristic

K

Number of poles (total)

2

Rated voltage

415V

Voltage type

Other

Rated current

0.2A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

6kV

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Power loss

2.2W

Current limiting class

-

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

100kA

Flush-mounted installation

Additional equipment possible

Pollution degree

3

Width in number of modular spacings

2.0

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Over voltage category

4

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-40 .. 70°C

Explosion-proof

Concurrently switching neutral conductor

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.