Aleta.hr
Main Product Image

2CDS382001R0131 | S302P-D13

Code: 1997215

ManufacturerABB
Catalog number2CDS382001R0131
EAN code4016779078917

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Release characteristicD
Number of protected poles2
Rated current13A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Power loss2.6W
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated impulse withstand voltage Uimp6kV
Rated voltage415V
Voltage typeOther
Current limiting class-
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Width in number of modular spacings2.0
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Over voltage category4
Pollution degree3
Flush-mounted installationNo
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0.75 - 25mm²
Connectable conductor cross section solid-core0.75 - 35mm²
Ambient temperature during operating-40 - 70°C
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS382001R0131 | S302P-D13

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Release characteristic

D

Number of protected poles

2

Rated current

13A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Power loss

2.6W

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated impulse withstand voltage Uimp

6kV

Rated voltage

415V

Voltage type

Other

Current limiting class

-

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Width in number of modular spacings

2.0

Concurrently switching neutral conductor

Additional equipment possible

Over voltage category

4

Pollution degree

3

Flush-mounted installation

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-40 .. 70°C

Explosion-proof

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.