Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Voltage typeOther
Rated current0.75A
Rated voltage415V
Frequency50 - 60Hz
Width in number of modular spacings2.0
Current limiting class-
Number of protected poles2
Pollution degree3
Release characteristicK
Rated insulation voltage Ui500V
Over voltage category4
Degree of protection (IP)IP20
Power loss2.2W
Explosion-proofNo
Additional equipment possibleYes
Ambient temperature during operating-40 - 70°C
Connectable conductor cross section multi-wired0.75 - 25mm²
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core0.75 - 35mm²
Flush-mounted installationNo
Rated impulse withstand voltage Uimp6kV
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V100kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS382001R0187 | S302P-K0.75

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Voltage type

Other

Rated current

0.75A

Rated voltage

415V

Frequency

50 .. 60Hz

Width in number of modular spacings

2.0

Current limiting class

-

Number of protected poles

2

Pollution degree

3

Release characteristic

K

Rated insulation voltage Ui

500V

Over voltage category

4

Degree of protection (IP)

IP20

Power loss

2.2W

Explosion-proof

Additional equipment possible

Ambient temperature during operating

-40 .. 70°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0.75 .. 35mm²

Flush-mounted installation

Rated impulse withstand voltage Uimp

6kV

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

100kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.