Aleta.hr
Main Product Image

2CDS382001R0205 | S302P-B20

Code: 1997226

ManufacturerABB
Catalog number2CDS382001R0205
EAN code4016779078801

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)2
Rated current20A
Number of protected poles2
Built-in depth69mm
Release characteristicB
Rated voltage415V
Voltage typeOther
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated impulse withstand voltage Uimp6kV
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Current limiting class-
Power loss4.6W
Pollution degree3
Over voltage category4
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Ambient temperature during operating-40 - 70°C
Width in number of modular spacings2.0
Additional equipment possibleYes
Explosion-proofNo
Connectable conductor cross section solid-core0.75 - 35mm²
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS382001R0205 | S302P-B20

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Rated current

20A

Number of protected poles

2

Built-in depth

69mm

Release characteristic

B

Rated voltage

415V

Voltage type

Other

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated impulse withstand voltage Uimp

6kV

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Current limiting class

-

Power loss

4.6W

Pollution degree

3

Over voltage category

4

Concurrently switching neutral conductor

Flush-mounted installation

Ambient temperature during operating

-40 .. 70°C

Width in number of modular spacings

2.0

Additional equipment possible

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0.75 .. 25mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.