Technical specifications

Rated voltage415V
Built-in depth69mm
Rated insulation voltage Ui500V
Number of protected poles2
Rated current1.6A
Release characteristicK
Number of poles (total)2
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V100kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Frequency50 - 60Hz
Power loss2.6W
Current limiting class-
Additional equipment possibleYes
Connectable conductor cross section multi-wired0.75 - 25mm²
Width in number of modular spacings2.0
Over voltage category4
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Pollution degree3
Degree of protection (IP)IP20
Ambient temperature during operating-40 - 70°C
Explosion-proofNo
Connectable conductor cross section solid-core0.75 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS382001R0257 | S302P-K1.6

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

415V

Built-in depth

69mm

Rated insulation voltage Ui

500V

Number of protected poles

2

Rated current

1.6A

Release characteristic

K

Number of poles (total)

2

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

100kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Frequency

50 .. 60Hz

Power loss

2.6W

Current limiting class

-

Additional equipment possible

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Width in number of modular spacings

2.0

Over voltage category

4

Flush-mounted installation

Concurrently switching neutral conductor

Pollution degree

3

Degree of protection (IP)

IP20

Ambient temperature during operating

-40 .. 70°C

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²