Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Voltage typeOther
Rated voltage415V
Frequency50 - 60Hz
Rated insulation voltage Ui500V
Current limiting class-
Release characteristicZ
Connectable conductor cross section solid-core0.75 - 35mm²
Number of protected poles2
Width in number of modular spacings2.0
Pollution degree3
Rated current1.6A
Explosion-proofNo
Power loss4.8W
Over voltage category4
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Additional equipment possibleYes
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-40 - 70°C
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V100kA
Flush-mounted installationNo
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS382001R0258 | S302P-Z1.6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Voltage type

Other

Rated voltage

415V

Frequency

50 .. 60Hz

Rated insulation voltage Ui

500V

Current limiting class

-

Release characteristic

Z

Connectable conductor cross section solid-core

0.75 .. 35mm²

Number of protected poles

2

Width in number of modular spacings

2.0

Pollution degree

3

Rated current

1.6A

Explosion-proof

Power loss

4.8W

Over voltage category

4

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Additional equipment possible

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-40 .. 70°C

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

100kA

Flush-mounted installation

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.