Aleta.hr
Main Product Image

2CDS382001R0258 | S302P-Z1.6

Code: 1997233

ManufacturerABB
Catalog number2CDS382001R0258
EAN code4016779078733

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage415V
Number of poles (total)2
Built-in depth69mm
Rated current1.6A
Rated insulation voltage Ui500V
Release characteristicZ
Number of protected poles2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V100kA
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Voltage typeOther
Frequency50 - 60Hz
Power loss4.8W
Current limiting class-
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Pollution degree3
Over voltage category4
Additional equipment possibleYes
Width in number of modular spacings2.0
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0.75 - 25mm²
Connectable conductor cross section solid-core0.75 - 35mm²
Ambient temperature during operating-40 - 70°C
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS382001R0258 | S302P-Z1.6

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

415V

Number of poles (total)

2

Built-in depth

69mm

Rated current

1.6A

Rated insulation voltage Ui

500V

Release characteristic

Z

Number of protected poles

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

100kA

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Voltage type

Other

Frequency

50 .. 60Hz

Power loss

4.8W

Current limiting class

-

Concurrently switching neutral conductor

Flush-mounted installation

Pollution degree

3

Over voltage category

4

Additional equipment possible

Width in number of modular spacings

2.0

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-40 .. 70°C

Explosion-proof

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.