Technical specifications

Rated insulation voltage Ui500V
Rated current6A
Current limiting class-
Voltage typeOther
Release characteristicK
Built-in depth69mm
Rated voltage415V
Frequency50 - 60Hz
Over voltage category4
Pollution degree3
Width in number of modular spacings2.0
Degree of protection (IP)IP20
Rated impulse withstand voltage Uimp6kV
Explosion-proofNo
Power loss3.2W
Ambient temperature during operating-40 - 70°C
Number of poles (total)2
Number of protected poles2
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core0.75 - 35mm²
Additional equipment possibleYes
Connectable conductor cross section multi-wired0.75 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V100kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS382001R0377 | S302P-K6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

500V

Rated current

6A

Current limiting class

-

Voltage type

Other

Release characteristic

K

Built-in depth

69mm

Rated voltage

415V

Frequency

50 .. 60Hz

Over voltage category

4

Pollution degree

3

Width in number of modular spacings

2.0

Degree of protection (IP)

IP20

Rated impulse withstand voltage Uimp

6kV

Explosion-proof

Power loss

3.2W

Ambient temperature during operating

-40 .. 70°C

Number of poles (total)

2

Number of protected poles

2

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0.75 .. 35mm²

Additional equipment possible

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

100kA