Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Built-in depth69mm
Current limiting class-
Width in number of modular spacings2.0
Release characteristicD
Rated voltage415V
Power loss6.8W
Rated current50A
Frequency50 - 60Hz
Degree of protection (IP)IP20
Over voltage category4
Rated insulation voltage Ui500V
Pollution degree3
Connectable conductor cross section solid-core0.75 - 35mm²
Number of protected poles2
Concurrently switching neutral conductorNo
Explosion-proofNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Flush-mounted installationNo
Ambient temperature during operating-40 - 70°C
Number of poles (total)2
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS382001R0501 | S302P-D50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Built-in depth

69mm

Current limiting class

-

Width in number of modular spacings

2.0

Release characteristic

D

Rated voltage

415V

Power loss

6.8W

Rated current

50A

Frequency

50 .. 60Hz

Degree of protection (IP)

IP20

Over voltage category

4

Rated insulation voltage Ui

500V

Pollution degree

3

Connectable conductor cross section solid-core

0.75 .. 35mm²

Number of protected poles

2

Concurrently switching neutral conductor

Explosion-proof

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Flush-mounted installation

Ambient temperature during operating

-40 .. 70°C

Number of poles (total)

2

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA