Aleta.hr
Main Product Image

2CDS382001R0518 | S302P-Z25

Code: 1997259

ManufacturerABB
Catalog number2CDS382001R0518
EAN code4016779078450

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles2
Release characteristicZ
Rated voltage415V
Number of poles (total)2
Current limiting class-
Frequency50 - 60Hz
Power loss6.6W
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated current25A
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Voltage typeOther
Built-in depth69mm
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Width in number of modular spacings2.0
Over voltage category4
Degree of protection (IP)IP20
Ambient temperature during operating-40 - 70°C
Pollution degree3
Connectable conductor cross section multi-wired0.75 - 25mm²
Additional equipment possibleYes
Connectable conductor cross section solid-core0.75 - 35mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS382001R0518 | S302P-Z25

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

2

Release characteristic

Z

Rated voltage

415V

Number of poles (total)

2

Current limiting class

-

Frequency

50 .. 60Hz

Power loss

6.6W

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated current

25A

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Voltage type

Other

Built-in depth

69mm

Flush-mounted installation

Concurrently switching neutral conductor

Width in number of modular spacings

2.0

Over voltage category

4

Degree of protection (IP)

IP20

Ambient temperature during operating

-40 .. 70°C

Pollution degree

3

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Additional equipment possible

Connectable conductor cross section solid-core

0.75 .. 35mm²

Explosion-proof

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.