Aleta.hr
Main Product Image

2CDS382001R0537 | S302P-K32

Code: 1997260

ManufacturerABB
Catalog number2CDS382001R0537
EAN code4016779078443

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles2
Rated voltage415V
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated current32A
Release characteristicK
Built-in depth69mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V20kA
Rated impulse withstand voltage Uimp6kV
Current limiting class-
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Voltage typeOther
Rated insulation voltage Ui500V
Power loss5.8W
Frequency50 - 60Hz
Flush-mounted installationNo
Degree of protection (IP)IP20
Additional equipment possibleYes
Connectable conductor cross section solid-core0.75 - 35mm²
Over voltage category4
Ambient temperature during operating-40 - 70°C
Concurrently switching neutral conductorNo
Width in number of modular spacings2.0
Pollution degree3
Explosion-proofNo
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS382001R0537 | S302P-K32

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

2

Rated voltage

415V

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated current

32A

Release characteristic

K

Built-in depth

69mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

20kA

Rated impulse withstand voltage Uimp

6kV

Current limiting class

-

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Voltage type

Other

Rated insulation voltage Ui

500V

Power loss

5.8W

Frequency

50 .. 60Hz

Flush-mounted installation

Degree of protection (IP)

IP20

Additional equipment possible

Connectable conductor cross section solid-core

0.75 .. 35mm²

Over voltage category

4

Ambient temperature during operating

-40 .. 70°C

Concurrently switching neutral conductor

Width in number of modular spacings

2.0

Pollution degree

3

Explosion-proof

Connectable conductor cross section multi-wired

0.75 .. 25mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.