Aleta.hr
Main Product Image

2CDS382001R0557 | S302P-K40

Code: 1997262

ManufacturerABB
Catalog number2CDS382001R0557
EAN code4016779078429

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Rated voltage415V
Rated impulse withstand voltage Uimp6kV
Number of protected poles2
Release characteristicK
Number of poles (total)2
Rated current40A
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V40kA
Power loss6.8W
Voltage typeOther
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Current limiting class-
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V20kA
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Pollution degree3
Width in number of modular spacings2.0
Connectable conductor cross section solid-core0.75 - 35mm²
Over voltage category4
Flush-mounted installationNo
Additional equipment possibleYes
Ambient temperature during operating-40 - 70°C
Explosion-proofNo
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS382001R0557 | S302P-K40

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Rated voltage

415V

Rated impulse withstand voltage Uimp

6kV

Number of protected poles

2

Release characteristic

K

Number of poles (total)

2

Rated current

40A

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Power loss

6.8W

Voltage type

Other

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

20kA

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Pollution degree

3

Width in number of modular spacings

2.0

Connectable conductor cross section solid-core

0.75 .. 35mm²

Over voltage category

4

Flush-mounted installation

Additional equipment possible

Ambient temperature during operating

-40 .. 70°C

Explosion-proof

Connectable conductor cross section multi-wired

0.75 .. 25mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.