Aleta.hr
Main Product Image

2CDS383001R0034 | S303P-C3

Code: 1997280

ManufacturerABB
Catalog number2CDS383001R0034
EAN code4016779078245

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current3A
Built-in depth69mm
Number of poles (total)3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Number of protected poles3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Current limiting class-
Power loss4.2W
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp6kV
Rated voltage415V
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V100kA
Voltage typeOther
Release characteristicC
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Over voltage category4
Flush-mounted installationNo
Pollution degree3
Connectable conductor cross section solid-core0.75 - 35mm²
Width in number of modular spacings3.0
Ambient temperature during operating-40 - 70°C
Connectable conductor cross section multi-wired0.75 - 25mm²
Explosion-proofNo
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS383001R0034 | S303P-C3

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

3A

Built-in depth

69mm

Number of poles (total)

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Number of protected poles

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Current limiting class

-

Power loss

4.2W

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

6kV

Rated voltage

415V

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

100kA

Voltage type

Other

Release characteristic

C

Additional equipment possible

Concurrently switching neutral conductor

Over voltage category

4

Flush-mounted installation

Pollution degree

3

Connectable conductor cross section solid-core

0.75 .. 35mm²

Width in number of modular spacings

3.0

Ambient temperature during operating

-40 .. 70°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Explosion-proof

Degree of protection (IP)

IP20

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.