Aleta.hr
Main Product Image

2CDS383001R0105 | S303P-B10

Code: 1997289

ManufacturerABB
Catalog number2CDS383001R0105
EAN code4016779078139

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage415V
Number of poles (total)3
Release characteristicB
Voltage typeOther
Built-in depth69mm
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated current10A
Number of protected poles3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Power loss4.2W
Current limiting class-
Over voltage category4
Additional equipment possibleYes
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Pollution degree3
Width in number of modular spacings3.0
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-40 - 70°C
Connectable conductor cross section solid-core0.75 - 35mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS383001R0105 | S303P-B10

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

415V

Number of poles (total)

3

Release characteristic

B

Voltage type

Other

Built-in depth

69mm

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated current

10A

Number of protected poles

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Power loss

4.2W

Current limiting class

-

Over voltage category

4

Additional equipment possible

Flush-mounted installation

Concurrently switching neutral conductor

Pollution degree

3

Width in number of modular spacings

3.0

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-40 .. 70°C

Connectable conductor cross section solid-core

0.75 .. 35mm²

Explosion-proof

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.