Rated insulation voltage Ui500V
Current limiting class-
Release characteristicK
Frequency50 - 60Hz
Built-in depth69mm
Rated current2A
Voltage typeOther
Pollution degree3
Explosion-proofNo
Rated voltage415V
Over voltage category4
Width in number of modular spacings3.0
Number of protected poles3
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Power loss3.9W
Additional equipment possibleYes
Number of poles (total)3
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V100kA
Ambient temperature during operating-40 - 70°C
Rated impulse withstand voltage Uimp6kV
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS383001R0277 | S303P-K2

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

500V

Current limiting class

-

Release characteristic

K

Frequency

50 .. 60Hz

Built-in depth

69mm

Rated current

2A

Voltage type

Other

Pollution degree

3

Explosion-proof

Rated voltage

415V

Over voltage category

4

Width in number of modular spacings

3.0

Number of protected poles

3

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Power loss

3.9W

Additional equipment possible

Number of poles (total)

3

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

100kA

Ambient temperature during operating

-40 .. 70°C

Rated impulse withstand voltage Uimp

6kV

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA