Technical specifications

Number of protected poles3
Rated voltage415V
Built-in depth69mm
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp6kV
Rated current2A
Number of poles (total)3
Release characteristicK
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Power loss3.9W
Frequency50 - 60Hz
Current limiting class-
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V100kA
Over voltage category4
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Ambient temperature during operating-40 - 70°C
Pollution degree3
Connectable conductor cross section multi-wired0.75 - 25mm²
Explosion-proofNo
Connectable conductor cross section solid-core0.75 - 35mm²
Degree of protection (IP)IP20
Additional equipment possibleYes
Width in number of modular spacings3.0
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS383001R0277 | S303P-K2

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

3

Rated voltage

415V

Built-in depth

69mm

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

6kV

Rated current

2A

Number of poles (total)

3

Release characteristic

K

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Power loss

3.9W

Frequency

50 .. 60Hz

Current limiting class

-

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

100kA

Over voltage category

4

Flush-mounted installation

Concurrently switching neutral conductor

Ambient temperature during operating

-40 .. 70°C

Pollution degree

3

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

Degree of protection (IP)

IP20

Additional equipment possible

Width in number of modular spacings

3.0