Aleta.hr
Main Product Image

2CDS383001R0321 | S303P-D32

Code: 1997314

ManufacturerABB
Catalog number2CDS383001R0321
EAN code4016779077880

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles3
Rated voltage415V
Built-in depth69mm
Voltage typeOther
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V20kA
Number of poles (total)3
Rated impulse withstand voltage Uimp6kV
Power loss8.7W
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Frequency50 - 60Hz
Release characteristicD
Rated current32A
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Current limiting class-
Explosion-proofNo
Pollution degree3
Over voltage category4
Ambient temperature during operating-40 - 70°C
Degree of protection (IP)IP20
Additional equipment possibleYes
Flush-mounted installationNo
Width in number of modular spacings3.0
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Connectable conductor cross section solid-core0.75 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS383001R0321 | S303P-D32

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

3

Rated voltage

415V

Built-in depth

69mm

Voltage type

Other

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

20kA

Number of poles (total)

3

Rated impulse withstand voltage Uimp

6kV

Power loss

8.7W

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Frequency

50 .. 60Hz

Release characteristic

D

Rated current

32A

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Current limiting class

-

Explosion-proof

Pollution degree

3

Over voltage category

4

Ambient temperature during operating

-40 .. 70°C

Degree of protection (IP)

IP20

Additional equipment possible

Flush-mounted installation

Width in number of modular spacings

3.0

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Connectable conductor cross section solid-core

0.75 .. 35mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.