Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Number of poles (total)3
Rated impulse withstand voltage Uimp6kV
Rated current10A
Built-in depth69mm
Rated voltage415V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Release characteristicK
Current limiting class-
Voltage typeOther
Frequency50 - 60Hz
Number of protected poles3
Power loss3.9W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Over voltage category4
Explosion-proofNo
Pollution degree3
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0.75 - 25mm²
Additional equipment possibleYes
Flush-mounted installationNo
Width in number of modular spacings3.0
Ambient temperature during operating-40 - 70°C
Connectable conductor cross section solid-core0.75 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS383001R0427 | S303P-K10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Number of poles (total)

3

Rated impulse withstand voltage Uimp

6kV

Rated current

10A

Built-in depth

69mm

Rated voltage

415V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Release characteristic

K

Current limiting class

-

Voltage type

Other

Frequency

50 .. 60Hz

Number of protected poles

3

Power loss

3.9W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Over voltage category

4

Explosion-proof

Pollution degree

3

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Additional equipment possible

Flush-mounted installation

Width in number of modular spacings

3.0

Ambient temperature during operating

-40 .. 70°C

Connectable conductor cross section solid-core

0.75 .. 35mm²