Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui500V
Number of protected poles3
Release characteristicD
Built-in depth69mm
Rated current50A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Frequency50 - 60Hz
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Voltage typeOther
Current limiting class-
Power loss10.2W
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Number of poles (total)3
Rated voltage415V
Flush-mounted installationNo
Pollution degree3
Additional equipment possibleYes
Explosion-proofNo
Ambient temperature during operating-40 - 70°C
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Width in number of modular spacings3.0
Over voltage category4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS383001R0501 | S303P-D50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

500V

Number of protected poles

3

Release characteristic

D

Built-in depth

69mm

Rated current

50A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Frequency

50 .. 60Hz

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Voltage type

Other

Current limiting class

-

Power loss

10.2W

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Number of poles (total)

3

Rated voltage

415V

Flush-mounted installation

Pollution degree

3

Additional equipment possible

Explosion-proof

Ambient temperature during operating

-40 .. 70°C

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Width in number of modular spacings

3.0

Over voltage category

4

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.