Rated voltage415V
Rated insulation voltage Ui500V
Built-in depth69mm
Rated current40A
Frequency50 - 60Hz
Release characteristicK
Voltage typeOther
Flush-mounted installationNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Over voltage category4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V40kA
Explosion-proofNo
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Additional equipment possibleYes
Connectable conductor cross section solid-core0.75 - 35mm²
Rated impulse withstand voltage Uimp6kV
Number of poles (total)3
Current limiting class-
Ambient temperature during operating-40 - 70°C
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Number of protected poles3
Power loss10.2W
Pollution degree3
Width in number of modular spacings3.0
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V20kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS383001R0557 | S303P-K40

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

415V

Rated insulation voltage Ui

500V

Built-in depth

69mm

Rated current

40A

Frequency

50 .. 60Hz

Release characteristic

K

Voltage type

Other

Flush-mounted installation

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Over voltage category

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Explosion-proof

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Additional equipment possible

Connectable conductor cross section solid-core

0.75 .. 35mm²

Rated impulse withstand voltage Uimp

6kV

Number of poles (total)

3

Current limiting class

-

Ambient temperature during operating

-40 .. 70°C

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Number of protected poles

3

Power loss

10.2W

Pollution degree

3

Width in number of modular spacings

3.0

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

20kA