Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicK
Number of poles (total)4
Rated insulation voltage Ui500V
Number of protected poles3
Rated impulse withstand voltage Uimp6kV
Power loss4.4W
Rated current0.2A
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Voltage typeOther
Built-in depth69mm
Rated voltage415V
Current limiting class-
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V100kA
Connectable conductor cross section solid-core0.75 - 35mm²
Ambient temperature during operating-40 - 70°C
Over voltage category4
Degree of protection (IP)IP20
Explosion-proofNo
Width in number of modular spacings4.0
Additional equipment possibleYes
Flush-mounted installationNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Concurrently switching neutral conductorYes
Pollution degree3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS383103R0087 | S303P-K0.2NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

K

Number of poles (total)

4

Rated insulation voltage Ui

500V

Number of protected poles

3

Rated impulse withstand voltage Uimp

6kV

Power loss

4.4W

Rated current

0.2A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Voltage type

Other

Built-in depth

69mm

Rated voltage

415V

Current limiting class

-

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

100kA

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-40 .. 70°C

Over voltage category

4

Degree of protection (IP)

IP20

Explosion-proof

Width in number of modular spacings

4.0

Additional equipment possible

Flush-mounted installation

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Concurrently switching neutral conductor

Pollution degree

3

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.