Built-in depth69mm
Number of poles (total)4
Rated insulation voltage Ui500V
Rated voltage415V
Rated current0.75A
Number of protected poles3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated impulse withstand voltage Uimp6kV
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V100kA
Power loss4.4W
Current limiting class-
Frequency50 - 60Hz
Release characteristicK
Flush-mounted installationNo
Pollution degree3
Degree of protection (IP)IP20
Over voltage category4
Additional equipment possibleYes
Width in number of modular spacings4.0
Explosion-proofNo
Concurrently switching neutral conductorYes
Connectable conductor cross section solid-core0.75 - 35mm²
Ambient temperature during operating-40 - 70°C
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS383103R0187 | S303P-K0.75NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Number of poles (total)

4

Rated insulation voltage Ui

500V

Rated voltage

415V

Rated current

0.75A

Number of protected poles

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated impulse withstand voltage Uimp

6kV

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

100kA

Power loss

4.4W

Current limiting class

-

Frequency

50 .. 60Hz

Release characteristic

K

Flush-mounted installation

Pollution degree

3

Degree of protection (IP)

IP20

Over voltage category

4

Additional equipment possible

Width in number of modular spacings

4.0

Explosion-proof

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-40 .. 70°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²