Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicZ
Built-in depth69mm
Number of poles (total)4
Number of protected poles3
Rated voltage415V
Rated current3A
Rated impulse withstand voltage Uimp6kV
Rated insulation voltage Ui500V
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V100kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Power loss8.8W
Frequency50 - 60Hz
Current limiting class-
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Concurrently switching neutral conductorYes
Over voltage category4
Additional equipment possibleYes
Pollution degree3
Width in number of modular spacings4.0
Connectable conductor cross section solid-core0.75 - 35mm²
Flush-mounted installationNo
Degree of protection (IP)IP20
Ambient temperature during operating-40 - 70°C
Explosion-proofNo
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS383103R0318 | S303P-Z3NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

Z

Built-in depth

69mm

Number of poles (total)

4

Number of protected poles

3

Rated voltage

415V

Rated current

3A

Rated impulse withstand voltage Uimp

6kV

Rated insulation voltage Ui

500V

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

100kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Power loss

8.8W

Frequency

50 .. 60Hz

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Concurrently switching neutral conductor

Over voltage category

4

Additional equipment possible

Pollution degree

3

Width in number of modular spacings

4.0

Connectable conductor cross section solid-core

0.75 .. 35mm²

Flush-mounted installation

Degree of protection (IP)

IP20

Ambient temperature during operating

-40 .. 70°C

Explosion-proof

Connectable conductor cross section multi-wired

0.75 .. 25mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.