Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Pollution degree3
Rated voltage415V
Frequency50 - 60Hz
Rated current50A
Release characteristicB
Voltage typeOther
Current limiting class-
Over voltage category4
Width in number of modular spacings4.0
Rated insulation voltage Ui500V
Built-in depth69mm
Explosion-proofNo
Number of poles (total)4
Ambient temperature during operating-40 - 70°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Connectable conductor cross section solid-core0.75 - 35mm²
Number of protected poles3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Connectable conductor cross section multi-wired0.75 - 25mm²
Rated impulse withstand voltage Uimp6kV
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Flush-mounted installationNo
Concurrently switching neutral conductorYes
Additional equipment possibleYes
Power loss14.8W
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS383103R0505 | S303P-B50NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Pollution degree

3

Rated voltage

415V

Frequency

50 .. 60Hz

Rated current

50A

Release characteristic

B

Voltage type

Other

Current limiting class

-

Over voltage category

4

Width in number of modular spacings

4.0

Rated insulation voltage Ui

500V

Built-in depth

69mm

Explosion-proof

Number of poles (total)

4

Ambient temperature during operating

-40 .. 70°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Connectable conductor cross section solid-core

0.75 .. 35mm²

Number of protected poles

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Rated impulse withstand voltage Uimp

6kV

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Flush-mounted installation

Concurrently switching neutral conductor

Additional equipment possible

Power loss

14.8W