Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeOther
Rated current63A
Built-in depth69mm
Rated voltage415V
Frequency50 - 60Hz
Rated insulation voltage Ui500V
Current limiting class-
Explosion-proofNo
Width in number of modular spacings4.0
Over voltage category4
Pollution degree3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Additional equipment possibleYes
Power loss24W
Ambient temperature during operating-40 - 70°C
Connectable conductor cross section solid-core0.75 - 35mm²
Degree of protection (IP)IP20
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V15kA
Connectable conductor cross section multi-wired0.75 - 25mm²
Number of protected poles3
Release characteristicB
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS383103R0635 | S303P-B63NA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

Other

Rated current

63A

Built-in depth

69mm

Rated voltage

415V

Frequency

50 .. 60Hz

Rated insulation voltage Ui

500V

Current limiting class

-

Explosion-proof

Width in number of modular spacings

4.0

Over voltage category

4

Pollution degree

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Additional equipment possible

Power loss

24W

Ambient temperature during operating

-40 .. 70°C

Connectable conductor cross section solid-core

0.75 .. 35mm²

Degree of protection (IP)

IP20

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

15kA

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Number of protected poles

3

Release characteristic

B

Flush-mounted installation

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.