Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated impulse withstand voltage Uimp6kV
Number of poles (total)4
Rated insulation voltage Ui500V
Current limiting class-
Rated voltage415V
Frequency50 - 60Hz
Rated current0.3A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Power loss4.4W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Number of protected poles4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V100kA
Voltage typeOther
Release characteristicK
Width in number of modular spacings4.0
Flush-mounted installationNo
Additional equipment possibleYes
Explosion-proofNo
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Over voltage category4
Ambient temperature during operating-40 - 70°C
Degree of protection (IP)IP20
Pollution degree3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS384001R0117 | S304P-K0.3

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated impulse withstand voltage Uimp

6kV

Number of poles (total)

4

Rated insulation voltage Ui

500V

Current limiting class

-

Rated voltage

415V

Frequency

50 .. 60Hz

Rated current

0.3A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Power loss

4.4W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Number of protected poles

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

100kA

Voltage type

Other

Release characteristic

K

Width in number of modular spacings

4.0

Flush-mounted installation

Additional equipment possible

Explosion-proof

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Over voltage category

4

Ambient temperature during operating

-40 .. 70°C

Degree of protection (IP)

IP20

Pollution degree

3

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.