Technical specifications

Frequency50 - 60Hz
Built-in depth69mm
Pollution degree3
Release characteristicD
Over voltage category4
Current limiting class-
Width in number of modular spacings4.0
Rated insulation voltage Ui500V
Voltage typeOther
Rated current13A
Rated voltage415V
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Number of protected poles4
Additional equipment possibleYes
Ambient temperature during operating-40 - 70°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Explosion-proofNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Power loss5.2W
Number of poles (total)4
Flush-mounted installationNo
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS384001R0131 | S304P-D13

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

50 .. 60Hz

Built-in depth

69mm

Pollution degree

3

Release characteristic

D

Over voltage category

4

Current limiting class

-

Width in number of modular spacings

4.0

Rated insulation voltage Ui

500V

Voltage type

Other

Rated current

13A

Rated voltage

415V

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Number of protected poles

4

Additional equipment possible

Ambient temperature during operating

-40 .. 70°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Explosion-proof

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Power loss

5.2W

Number of poles (total)

4

Flush-mounted installation

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²