Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)4
Built-in depth69mm
Rated current13A
Release characteristicC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Voltage typeOther
Rated impulse withstand voltage Uimp6kV
Rated insulation voltage Ui500V
Number of protected poles4
Rated voltage415V
Power loss5.2W
Frequency50 - 60Hz
Current limiting class-
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Width in number of modular spacings4.0
Flush-mounted installationNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-40 - 70°C
Over voltage category4
Additional equipment possibleYes
Pollution degree3
Degree of protection (IP)IP20
Connectable conductor cross section solid-core0.75 - 35mm²
Concurrently switching neutral conductorNo
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS384001R0134 | S304P-C13

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

4

Built-in depth

69mm

Rated current

13A

Release characteristic

C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Voltage type

Other

Rated impulse withstand voltage Uimp

6kV

Rated insulation voltage Ui

500V

Number of protected poles

4

Rated voltage

415V

Power loss

5.2W

Frequency

50 .. 60Hz

Current limiting class

-

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Width in number of modular spacings

4.0

Flush-mounted installation

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-40 .. 70°C

Over voltage category

4

Additional equipment possible

Pollution degree

3

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0.75 .. 35mm²

Concurrently switching neutral conductor

Explosion-proof

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.