Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicK
Number of protected poles4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Built-in depth69mm
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated voltage415V
Rated current0.5A
Power loss5.2W
Current limiting class-
Rated impulse withstand voltage Uimp6kV
Frequency50 - 60Hz
Number of poles (total)4
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V100kA
Explosion-proofNo
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core0.75 - 35mm²
Flush-mounted installationNo
Additional equipment possibleYes
Over voltage category4
Connectable conductor cross section multi-wired0.75 - 25mm²
Width in number of modular spacings4.0
Pollution degree3
Degree of protection (IP)IP20
Ambient temperature during operating-40 - 70°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS384001R0157 | S304P-K0.5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

K

Number of protected poles

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Built-in depth

69mm

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated voltage

415V

Rated current

0.5A

Power loss

5.2W

Current limiting class

-

Rated impulse withstand voltage Uimp

6kV

Frequency

50 .. 60Hz

Number of poles (total)

4

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

100kA

Explosion-proof

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0.75 .. 35mm²

Flush-mounted installation

Additional equipment possible

Over voltage category

4

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Width in number of modular spacings

4.0

Pollution degree

3

Degree of protection (IP)

IP20

Ambient temperature during operating

-40 .. 70°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.