Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)4
Built-in depth69mm
Rated current25A
Release characteristicD
Number of protected poles4
Rated insulation voltage Ui500V
Rated voltage415V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Power loss9.2W
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Current limiting class-
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Additional equipment possibleYes
Degree of protection (IP)IP20
Explosion-proofNo
Connectable conductor cross section solid-core0.75 - 35mm²
Over voltage category4
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Pollution degree3
Connectable conductor cross section multi-wired0.75 - 25mm²
Width in number of modular spacings4.0
Ambient temperature during operating-40 - 70°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS384001R0251 | S304P-D25

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

4

Built-in depth

69mm

Rated current

25A

Release characteristic

D

Number of protected poles

4

Rated insulation voltage Ui

500V

Rated voltage

415V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Power loss

9.2W

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Current limiting class

-

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Additional equipment possible

Degree of protection (IP)

IP20

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

Over voltage category

4

Flush-mounted installation

Concurrently switching neutral conductor

Pollution degree

3

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Width in number of modular spacings

4.0

Ambient temperature during operating

-40 .. 70°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.