Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)4
Release characteristicB
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Built-in depth69mm
Rated voltage415V
Voltage typeOther
Number of protected poles4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp6kV
Power loss9.2W
Rated current25A
Current limiting class-
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Flush-mounted installationNo
Pollution degree3
Additional equipment possibleYes
Width in number of modular spacings4.0
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Over voltage category4
Connectable conductor cross section multi-wired0.75 - 25mm²
Connectable conductor cross section solid-core0.75 - 35mm²
Ambient temperature during operating-40 - 70°C
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS384001R0255 | S304P-B25

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

4

Release characteristic

B

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Built-in depth

69mm

Rated voltage

415V

Voltage type

Other

Number of protected poles

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

6kV

Power loss

9.2W

Rated current

25A

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Flush-mounted installation

Pollution degree

3

Additional equipment possible

Width in number of modular spacings

4.0

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Over voltage category

4

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-40 .. 70°C

Explosion-proof

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.