Technical specifications

Built-in depth69mm
Voltage typeOther
Rated current2A
Frequency50 - 60Hz
Current limiting class-
Width in number of modular spacings4.0
Explosion-proofNo
Power loss5.2W
Concurrently switching neutral conductorNo
Rated voltage415V
Release characteristicK
Degree of protection (IP)IP20
Rated insulation voltage Ui500V
Additional equipment possibleYes
Number of poles (total)4
Over voltage category4
Number of protected poles4
Connectable conductor cross section multi-wired0.75 - 25mm²
Pollution degree3
Ambient temperature during operating-40 - 70°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated impulse withstand voltage Uimp6kV
Connectable conductor cross section solid-core0.75 - 35mm²
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V100kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS384001R0277 | S304P-K2

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Voltage type

Other

Rated current

2A

Frequency

50 .. 60Hz

Current limiting class

-

Width in number of modular spacings

4.0

Explosion-proof

Power loss

5.2W

Concurrently switching neutral conductor

Rated voltage

415V

Release characteristic

K

Degree of protection (IP)

IP20

Rated insulation voltage Ui

500V

Additional equipment possible

Number of poles (total)

4

Over voltage category

4

Number of protected poles

4

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Pollution degree

3

Ambient temperature during operating

-40 .. 70°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated impulse withstand voltage Uimp

6kV

Connectable conductor cross section solid-core

0.75 .. 35mm²

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

100kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.