Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)4
Built-in depth69mm
Release characteristicK
Rated impulse withstand voltage Uimp6kV
Number of protected poles4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V100kA
Rated voltage415V
Rated current3A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Rated insulation voltage Ui500V
Voltage typeOther
Power loss5.2W
Current limiting class-
Frequency50 - 60Hz
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Over voltage category4
Additional equipment possibleYes
Explosion-proofNo
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-40 - 70°C
Degree of protection (IP)IP20
Width in number of modular spacings4.0
Pollution degree3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS384001R0317 | S304P-K3

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

4

Built-in depth

69mm

Release characteristic

K

Rated impulse withstand voltage Uimp

6kV

Number of protected poles

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

100kA

Rated voltage

415V

Rated current

3A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated insulation voltage Ui

500V

Voltage type

Other

Power loss

5.2W

Current limiting class

-

Frequency

50 .. 60Hz

Flush-mounted installation

Concurrently switching neutral conductor

Over voltage category

4

Additional equipment possible

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-40 .. 70°C

Degree of protection (IP)

IP20

Width in number of modular spacings

4.0

Pollution degree

3

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.