Aleta.hr
Main Product Image

2CDS384001R0447 | S304P-K13

Code: 1997478

ManufacturerABB
Catalog number2CDS384001R0447
EAN code4016779076142

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)4
Release characteristicK
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated current13A
Number of protected poles4
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated voltage415V
Power loss7.2W
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V25kA
Frequency50 - 60Hz
Built-in depth69mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Current limiting class-
Rated impulse withstand voltage Uimp6kV
Flush-mounted installationNo
Width in number of modular spacings4.0
Degree of protection (IP)IP20
Ambient temperature during operating-40 - 70°C
Explosion-proofNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Additional equipment possibleYes
Connectable conductor cross section solid-core0.75 - 35mm²
Over voltage category4
Pollution degree3
Concurrently switching neutral conductorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS384001R0447 | S304P-K13

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

4

Release characteristic

K

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated current

13A

Number of protected poles

4

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated voltage

415V

Power loss

7.2W

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Frequency

50 .. 60Hz

Built-in depth

69mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Current limiting class

-

Rated impulse withstand voltage Uimp

6kV

Flush-mounted installation

Width in number of modular spacings

4.0

Degree of protection (IP)

IP20

Ambient temperature during operating

-40 .. 70°C

Explosion-proof

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Additional equipment possible

Connectable conductor cross section solid-core

0.75 .. 35mm²

Over voltage category

4

Pollution degree

3

Concurrently switching neutral conductor